Back to catalog

Hybrid Inverters

V Series Hybrid Inverters

8-15 kW hybrid inverter for residential and small commercial systems.

On request

Datasheet unavailable

Product description

Pytes V3PL(8-15)K is a high-performance 8-15 kW hybrid inverter designed to meet the demands of both residential and small commercial energy storage systems. With IP65 waterproof protection, dual AC input, and smart load management, it ensures stable power supply under various conditions. Built-in WiFi monitoring, scalable parallel operation, and customizable charging settings make this inverter a flexible, reliable, and future-ready solution for off-grid and hybrid solar applications.

Technical Specifications

Specifications

Specifications
ParameterValue
Rated PowerV3PL8K: 8000 W; V3PL10K: 10000 W; V3PL12K: 12000 W; V3PL15K: 15000 W

PV INPUT (DC)

PV INPUT (DC)
ParameterValue
Maximum DC PowerV3PL8K: 12000 W; V3PL10K: 15000; V3PL12K: 18000 W; V3PL15K: 22500 W
Nominal DC Voltage720 VDC
Maximum DC VoltageV3PL8K: 900 VDC; V3PL10K: 1000 VDC
Working DC Voltage RangeV3PL8K: 150 VDC ~ 900 VDC; V3PL10K: 300 VDC ~ 1000 VDC
Start-up Voltage / Initial Feeding VoltageV3PL8K: 150 VDC / 150 VDC; V3PL10K: 320 VDC / 350 VDC
MPP Voltage Range / Full Load MPP Voltage RangeV3PL8K: 150 VDC ~ 850 VDC / 400VDC ~ 850 VDC; V3PL10K: 150 VDC ~ 850 VDC / 420VDC ~ 850 VDC; V3PL12K: 150 VDC ~ 850 VDC / 400VDC ~ 850 VDC; V3PL15K: 350 VDC ~ 950 VDC / 348 VDC ~ 900 VDC
Number of MPP Trackers / Maximum Input CurrentV3PL8K: 2 /A: 15A, B:15A; V3PL10K: 2 /A: 18A, B:18A; V3PL12K: 2 /A: 27A, B:18A; V3PL15K: 2 / A: 26A, B:26A

GRID OUTPUT (AC)

GRID OUTPUT (AC)
ParameterValue
Nominal Output Voltage230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range184 - 265 VAC per phase
Output Frequency Range47.5 ~ 51.5 Hz or 59.3~ 60.5Hz
Nominal Output CurrentV3PL8K: 11.6A per phase; V3PL10K: 14.5A per phase; V3PL12K: 17.4A per phase; V3PL15K: 21.7A per phase
Inrush Current/Duration22 A per phase / 20ms
Maximum Output Fault Current/Duration66 A per phase / 1ms
Maximum output Overcurrent Protection66 A per phase
Power Factor Range0.9 lead – 0.9 lag

AC INPUT

AC INPUT
ParameterValue
AC Start-up Voltage120-140 VAC per phase
Auto Restart Voltage180 VAC per phase
Acceptable Input Voltage Range170 - 290 VAC per phase
Nominal Frequency50 Hz / 60 Hz
AC Input PowerV3PL8K: 8KVA/8KW; V3PL10K: 10KVA/10KW; V3PL12K: 12KVA/12KW; V3PL15K: 15KVA/15KW
Maximum AC Input Current40 A
Inrush Input Current40 A / 1ms

BATTERY MODE OUTPUT (AC)

BATTERY MODE OUTPUT (AC)
ParameterValue
Nominal Output Voltage230 VAC (P-N) / 400 VAC (P-P)
Output Frequency50 Hz / 60 Hz (auto sensing)
Output WaveformPure sine wave
Output PowerV3PL8K: 8KVA/8KW; V3PL10K: 10KVA/10KW; V3PL12K: 12KVA/12KW; V3PL15K: 15KVA/15KW
Efficiency (DC to AC)V3PL8K: 93%; V3PL10K: 91%

BATTERY & CHARGER (Lead-acid/Li-ion)

BATTERY & CHARGER (Lead-acid/Li-ion)
ParameterValue
DC Voltage RangeV3PL8K: 40 – 60 VDC; V3PL10K: 40 – 62 VDC
Nominal DC Voltage48 VDC
Maximum Battery Discharging CurrentV3PL8K: 200A; V3PL10K: 220A; V3PL12K: 240 A; V3PL15K: 375 A
Maximum Charging CurrentV3PL8K: 160A; V3PL10K: 200A; V3PL12K: 240 A; V3PL15K: 300 A

GENERAL — PHYSICAL

GENERAL — PHYSICAL
ParameterValue
Dimension, D X W X H (mm)247 x 500 x 650
Net Weight (kgs)V3PL8K: 50; V3PL10K: 54; V3PL12K: 73

GENERAL — INTERFACE

GENERAL — INTERFACE
ParameterValue
Communication PortRS-232/USB/RS485/CAN/WI-FI
Intelligent SlotOptional SNMP, Modbus cards available

GENERAL — ENVIRONMENT

GENERAL — ENVIRONMENT
ParameterValue
Protective ClassI
Ingress Protection RatingIP65
Humidity0 ~ 100% RH (No condensing)
Operating Temperature-25 to 60°C (Power derating above 45°C)
AltitudeMax. 1000m* * Power derating 1% every 100m when altitude is over 1000m.